Richmond 5v40-7 Water Heater Specs -
To maximize the lifespan, it is recommended to drain and flush the tank annually to remove sediment buildup, especially in hard water areas. Alternative Modern Options
Standard 40-gallon atmospheric gas heaters of this specific generation usually feature an input of roughly 36,000 to 40,000 BTU/h .
: First check the pilot light assembly. If the pilot flame refuses to stay lit after manual ignition, the thermocouple is likely worn out or misaligned and requires replacement.
A: No. The gas valve and pilot operate without any electrical connection. This makes it ideal for use during power outages. richmond 5v40-7 water heater specs
: Features a "4-hole top" or side-mounted openings for easier access and fast installation in tight quarters.
It is a natural gas water heater.
| Specification | Detail | |---------------|--------| | Vent Type | Type B (double-wall) or single-wall metal vent | | Vent Diameter | 3 inches | | Draft Hood | Included (integral) | | Maximum Vent Run | 20 feet horizontal run; unlimited vertical with proper draft | | Clearance to Combustibles | 6 inches (sides), 12 inches (front for service) | To maximize the lifespan, it is recommended to
To counter internal tank corrosion, the interior steel shell features a fused, high-temperature . This protective glass barrier shields the metal from aggressive water chemistry and mineral scaling, effectively preventing premature tank ruptures. 2. Four-Hole Top Configuration
Richmond is a subsidiary of Rheem, so the 5V40-7 shares many high-end engineering components found in more expensive units:
EverKleen Self-Cleaning SystemTo combat sediment buildup—the primary enemy of water heater longevity—this model utilizes an internal dip tube designed to create a high-velocity spiral of water. This motion keeps minerals in suspension so they are flushed out rather than settling at the bottom of the tank. If the pilot flame refuses to stay lit
Drain 5 to 10 gallons from the bottom brass valve every 12 months to remove calcium and lime sediment that insulates the burner from the water.
If you’d like, I can fetch the official spec sheet and list the exact element wattage, FHR and dimensions for the 5V40‑7
When operating the Richmond 5V40-7, ensure the following safety parameters are met:
Here are some general replacement options:
Unit Height: 50.5 inches (to the top of the water connections) Unit Diameter: 18 to 19 inches (standard slim profile) Ship Weight: Approximately 130 lbs Performance Metrics BTU Input: 36,000 BTU/h Recovery Rate: 36.4 Gallons per hour (at a 90°F rise) First Hour Rating: 67 Gallons